Pub.# OM17-PRC Operating Instruction Manual Precision Rate Controller Veris Technologies 601 N. Broadway Salina KS 67
Pub.# OM17-PRC 2-5 Figure 21. Console window now displays the calibration number you have selected. This returns you back to the beginning of Ca
Pub.# OM17-PRC 3-1 Calibration—Speed In order for the Precision Rate Controller to meter the proper amount of material, it must have an accurate f
Pub.# OM17-PRC 3-2 Figure 24 and 25. When the tractor passes the second flag, press engage again. (Figure 26) The display will show the error
Pub.# OM17-PRC 4-1 Field Operations 1. Once calibration procedure above has been followed, Console will store the calibration and rate informati
Pub.# OM17-PRC 4-2 5. Press Engage key to activate drive. Green light above Engage key will illuminate. After 20 seconds of no speed signal, dri
Pub.# OM17-PRC 5-1 Varying Rates with Pre-set Function The Veris Precision Rate Controller allows you to pre-set three different rates, and then c
Pub.# OM17-PRC 6-1 Varying Rates with GPS-Based Maps Settings for FarmWorks SiteMate used with Veris Precision Rate Controllers—QUICK REFERENCE GU
Pub.# OM17-PRC 6-2 Settings for Veris Precision Rate Controllers: 1. Connect SiteMate computer to Cab Console using 9-pin serial cable, as shown i
Pub.# OM17-PRC 6-3 Population Monitor rate does not match Veris Console. -Make certain that SiteMate and Console agree. If not, see Troubleshootin
Pub.# OM17-PRC 6-4 PF3000 Settings: 1. Press SETUP key. Press SWATH key. Set swath to that of your implement 2. Press SETUP key. Press VEHICL
Pub.# OM17-PRC Table of Contents Operational Requirements—Hydraulic and Electrical 1-1 Tractor Hookup 1-2 Console Functions
Pub.# OM17-PRC 6-5 Settings for Veris Precision Rate Controllers: 1. Connect PF3000 to Console using 9 pin serial cable as shown in Figure 33. 2.
Pub.# OM17-PRC 6-6 10. Population Monitor rate does not match Veris Console. -Make certain that PF3000 and Veris Console agree. If not, see Troubl
Pub.# OM17-PRC 7-1 Maintenance As with any hydraulic system, contamination is the most common cause of performance problems and pre-mature wear.
Pub.# OM17-PRC 8-1 Troubleshooting Drive will not rotate: (see Troubleshooting flow chart and electronics overview) 1. Check cab console: 1.1) No
Pub.# OM17-PRC 8-2 4. Check hydraulics: 4.1) Check to see if hydraulic lever is in detent position. 4.2) Hydraulic lever is in wrong detent directi
Pub.# OM17-PRC 8-3 Drive rotates but not at desired speed: 6. Drive (out rate) fluctuating erratically 6.1) If indicated field speed on drive is a
Pub.# OM17-PRC 8-4 10. Drive plants significantly higher than desired rate: 10.1) Re-check calibration number, and re-run calibration procedure if
Pub.# OM17-PRC 8-5 Calibration Troubleshooting: 13. If the time to run for calibration is less than 4 seconds, the cab console will display TIME TO
1-1 Operating Instructions Drive Operational Requirements: Hydraulic System: Closed center, pressure compensated or load sensed systems only Drive w
Pub.# OM17-PRC 1-2 Connect to power port Connect to console Connect to power wire from implement Figure 1 b) To battery. Make sure t
Pub.# OM17-PRC 1-3 Console Functions Shown below in Figure 3 is the Precision Population Controller Console. The uses of each key are as follows:
Pub.# OM17-PRC 2-1 Calibration--Rate Turn on Controller Console by pressing On/VR key. Green light above On/VR key will illuminate when power is
Pub.# OM17-PRC 2-2 Figure 7. This is the first window that appears in Calibration mode. Press Function key to accept, or Up key to change to met
Pub.# OM17-PRC 2-3 Figure 12. The cab console is informing you the length of time that the drive will be operating, in order to meter the amount
Pub.# OM17-PRC 2-4 Figure 16. While the drive is rotating, the display window shows the time remaining and the “Out” rate. CONTINUE TO MONITOR D